P2E71
Hybrid/EV Battery Pack B Cell Thickness Sensor Circuit High
P2E71 flags the thickness sensor circuit of pack B as reading too high. Not every swelling detector is analog: LG's module patent uses a panel that slides along a ramp until it touches a contact sensor, and a Lithium Energy and Power patent fits cells with insulated contact elements that close under pressure. Ford also describes a thin wire across a weakened cell wall that tears once the wall bulges, cutting the current through it. In such switch-type layouts an open circuit and a triggered sensor can look alike, so the controller needs a defined resting level to tell them apart. No manufacturer documents P2E71 publicly. Check connectors after pack B service first; low signal is P2E72.
Possible causes
- Sensor connector in pack B not fully seated after battery work high
- Broken signal or ground wire to the sensor medium
- Signal line shorted to a supply voltage low
Symptoms
- Hybrid or EV warning light
- Possibly limited power or charging
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2E71
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?