P2E6F
Hybrid/EV Battery Pack A Cell Thickness Sensor Circuit Performance
P2E6F covers a thickness sensor in pack A whose reading is electrically valid but does not behave as the controller expects. Cell thickness is not static: it rises and falls with state of charge, which is why Bosch and Samsung SDI propose using the swelling force of the winding to estimate charge and health, and a graphene film sensor studied at Warwick tracked charge level from expansion alone. A sensor that stays frozen while the pack is charged and discharged, or drifts against that pattern, is therefore suspect. Nebraska and Oak Ridge researchers found that expansion also depends on current, charge voltage and clamping force, so limits must be wide. No manufacturer documents P2E6F publicly. CARB asks for such rationality checks where feasible.
Possible causes
- Sensor loosened, shifted or no longer bonded to the cell or end plate high
- Sensor drifting with age or temperature medium
- Contact resistance in connectors distorting the reading medium
- Missing calibration or relearn after module replacement low
Symptoms
- Warning light without noticeable driving change at first
- Charging or power may be restricted later
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2E6F
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.