P2E6E
Hybrid/EV Battery Pack A Cell Thickness Sensor Circuit Low
P2E6E is the low-side counterpart to P2E6D: the thickness or swelling sensor of pack A delivers less signal than any intact circuit should, typically from a short to ground, a missing supply or a dead sensor amplifier. No manufacturer documents P2E6E publicly. Two patents show why a low reading can hide a real problem. LG places piezo elements in the cooling gap between cells; they produce a voltage only when expanding cells press on them, which the BMS evaluates. Bosch and Samsung SDI describe a pressure film around the electrode winding whose charge is turned into a voltage by an amplifier fed from the battery. If that output collapses, the controller can no longer see swelling, so it flags the circuit. CARB requires each out-of-range fault of an input to be stored separately.
Possible causes
- Signal wire shorted to ground or to the module housing high
- Sensor supply or amplifier supply missing medium
- Sensing element or its amplifier failed medium
- Moisture or coolant in a connector inside the pack creating a leakage path low
Symptoms
- Hybrid or EV warning light
- Reduced power or limited charging
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2E6E
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.