P2E43
Hybrid/EV Electronics Coolant Pump B Control Circuit Low
P2E43 means the command signal of electronics coolant pump B sits too low, typically because the line has contact with ground or the output stage cannot drive it up. On PWM-controlled pumps this usually stops the pump outright. Pierburg's CWA pumps, a widespread design, read a duty cycle of 0 to 1 % as stop and pull their PWM input to ground through 10 kΩ, so a grounded line leaves the rotor standing. Ford's 2024 summary treats circuit low (fault type 11) on its auxiliary pumps as a report from the smart driver, checked over 5 s at a battery voltage of at least 11 V. GM's 2016 hybrid tables fold grounded, voltage-shorted and open lines into a single pump A code, P0CE9. No manufacturer publicly documents P2E43. Chafed insulation and wet connectors are usual finds. The high-side code is P2E44, pump A's version P0CEB.
Possible causes
- Control wire chafed through and shorted to ground high
- Moisture or corrosion bridging pins in the pump connector medium
- Shorted input stage inside pump B medium
- Output stage of the module stuck low low
Symptoms
- Pump B stops, electronics coolant heats up
- MIL with hybrid or drive system message
- Limited power or charging rate under load
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2E43
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.
Sources
- tecomotive.com/download/PWMinfo_EN.pdf
- tecomotive.com/download/datasheets/CWA100_EN.pdf
- fordservicecontent.com/Ford_Content/catalog/motorcraft/OBDSM2400OUTPUT_16Jul2024_WSM_final_V2_MCS7001.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2016/16OBDG01 Hybrid Diagnostics.pdf
- law.cornell.edu/regulations/california/13-CCR-1968.2