Powertrain
generic / SAE
P2E3E
Battery Charger B Module Forced Shutdown Voltage Performance
The forced shutdown voltage feedback of battery charger B is performance. Safety shutdown line may be compromised.
SystemPowertrain
Typegeneric / SAE
GroupP2
Range / numberE / 3E
Possible causes
- Forced shutdown wire fault high
- Module shutdown circuit fault medium
Symptoms
- Charge status indicator shows fault
- Charging may not start or interrupts
- Slower-than-expected charge rate
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
- Estimated cost: 300–2000 €
- Estimated time: 2–6 h
- Component: battery charger b shutdown circuit
- Component: wiring harness
- MIL / check engine light
- limp mode possible
Sources
References
sae:J2012