P2E3E
Battery Charger B Module Forced Shutdown Voltage Performance
P2E3E is the charger B version of P2E32: the forced shutdown signal of the second charger is electrically in range but its behaviour is implausible. Examples are a shutdown request that the charger ignores, or a level that changes state without a matching command, so the control unit can no longer trust its hardwired off-switch for path B. No manufacturer documents P2E3E or the underlying circuit publicly. What such a line is for can be seen at Watt & Well, whose EVCC controller ends a charging session in hardware as soon as current in its EmShut loop vanishes. CARB demands that plug-in hybrids detect charger faults that prevent or degrade charging. Its low and high faults are P2E3F/P2E40. Expect charger B to be locked out; a first charger may keep charging at reduced power.
Possible causes
- Shutdown input stage inside charger B not responding correctly medium
- Intermittent contact in the charger B shutdown line medium
- Software issue in the module issuing the shutdown low
Symptoms
- Charging slower than usual because charger B is locked out
- Charging system warning message
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P2E3E
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.