P2E35
Battery Charger B Enable Circuit/Open
P2E35 covers the enable line of charger B, the hardwired 12 V signal that wakes the charger or allows it to work, and reports a general circuit fault, usually an open. No manufacturer documents P2E35 publicly. The A-side code P0E61 is documented by GM: the 2016 Volt (VICM) and the 2019 hybrid tables (HPC2) evaluate a fault flag from the line driver at 10.2 V system voltage or more, 30 bad samples out of 40 at 25 ms, Type B. Holley's 30-8405 charger unit shows why the line counts: the charger only runs with 12 V on its wake-up pin, and without it even its CAN stays silent. Specific level faults are P2E36 and P2E37, plausibility P2E38. With an open line charger B stays asleep; a car with a second charger may still charge slowly through the first.
Possible causes
- Broken enable wire or backed-out terminal high
- Signal connector at charger B not fully latched medium
- Failed enable driver in the commanding module low
Symptoms
- Charger B does not wake when the cable is plugged in
- Charging slower than usual or not at all
- Charging system warning message
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P2E35
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.