P2E30
Battery Charger B Module Supply Voltage Low
P2E30 is stored when the 12 V feed reaching the control board of charger B stays under its lower limit. Most causes lie upstream: a flat or aged 12 V battery, a blown fuse or failed relay in the charger feed, or corroded supply and ground contacts that lose voltage under load. No manufacturer documents P2E30 publicly, and no threshold is published. For a sense of scale, Holley's 30-8405 charger unit names 9–16 V as its normal range and keeps CAN alive only down to 6 V; Mitsubishi's Outlander PHEV lists a faulty charger supply circuit among the causes of lost communication with the charger (U019B). Under CARB rules a charger fault that blocks charging must be flagged. Too high is P2E31, charger A low is P2E2D. Charging via path B is likely refused; driving normally continues.
Possible causes
- Discharged or aged 12 V battery high
- Blown fuse or failed relay in the charger B feed medium
- Voltage drop across corroded supply or ground contacts medium
- DC/DC converter not holding up the 12 V network low
Symptoms
- Charging through charger B does not start
- Low-voltage or communication faults in other modules too
- Reduced charging power if only one charger works
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P2E30
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.