P2E2A
Drive Motor A Excitation Current Sensor Circuit High Voltage
P2E2A is the counterpart to P2E29: the signal from the sensor that measures the rotor field current of drive motor A sits above the highest voltage a working sensor can deliver. Typical reasons are a signal line touching a supply rail, an open ground or reference connection that lets the input float up, or a failed sensor output stage. Electrically excited traction motors, such as BMW's fifth-generation eDrive units, rely on this measurement to set rotor flux, because the field current sets how strong the rotor's magnetic field is. No manufacturer documents P2E2A publicly. It must not be confused with P2E2B, where the current itself is too high; a merely implausible value is P2E28. Expect a drive system warning and loss of power from this motor until the fault is repaired.
Possible causes
- Sensor signal line shorted to a supply voltage high
- Open sensor ground or reference connection medium
- Failed sensor output stage medium
Symptoms
- Electric drive warning lamp on
- Reduced or no drive power
- Fault returns immediately after clearing
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2E2A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.