P2E1E
Drive Motor A Phase X Current Sensor Circuit High
P2E1E flags a phase X current sensor signal of drive motor A above the top of its valid range. No manufacturer documents P2E1E publicly. GM's U-phase counterpart on the 2016 Volt trips above 700 A for 0.05 s within 0.1 s, Type A. The same table stops real overcurrent at 600 A through P0C01, and Ford's 2019 hybrids treat more than 600 A for 400 microseconds as motor overcurrent. The sensor limit thus lies beyond any current the inverter would tolerate, so a reading that high almost always comes from the measuring side, for instance a signal shorted to the sensor supply or an open sensor ground. Genuine excess current in phase X is P2C6B. The inverter limits or stops drive. Low side: P2E1D.
Possible causes
- Sensor signal shorted to the sensor supply high
- Open ground of the phase X current sensor medium
- Phase X current sensor failed high medium
Symptoms
- Hybrid warning lamp and MIL
- Electric drive cut off or strongly limited
- Possible jolt when the inverter shuts down
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2E1E
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.