P2E1B
Drive Motor A Phase X Current Sensor Circuit
P2E1B reports an electrical fault in the circuit of the phase X current sensor of drive motor A, without a separate low or high verdict. X, Y and Z name a second three-phase winding group: a Mitsubishi Electric patent on two-group motors for hybrid drives couples one current sensor to the conductor of each of the six phases. No manufacturer documents P2E1B publicly. Ford's 2019 hybrids supervise a reference voltage for the motor current sensors and flag it outside 4.5 to 6 V for 500 ms; a fault there would hit every phase at once. CARB allows a sensor mounted on a board inside a control unit to report wiring and range faults under one shared code, so P2E1B may stand in for P2E1D and P2E1E. Since the sensor sits in the inverter, the repair is usually that unit.
Possible causes
- Phase X current sensor in the inverter failed high
- Reference supply or ground of the current sensors faulty medium
- Loose or corroded low-voltage connector at the inverter medium
- Defect on the motor control board that evaluates the sensor low
Symptoms
- Hybrid system warning lamp and MIL
- Reduced electric drive or no electric drive
- Rough or noisy motor operation under load
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2E1B