Powertrain
generic / SAE
P2E17
Intermediate Shaft Selection Actuator Position Sensor Circuit Low
The ECM detects a circuit low fault on the intermediate shaft selection actuator position sensor. Reading cannot be used reliably for control.
SystemPowertrain
Typegeneric / SAE
GroupP2
Range / numberE / 17
Possible causes
- Signal wire shorted to ground high
- Internal sensor short medium
- Connector pins corroded - high contact resistance low
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
- Estimated cost: 200–1000 €
- Estimated time: 1–4 h
- Component: intermediate shaft selection actuator position sensor
- Component: wiring harness
- Component: tcm
- MIL / check engine light
- limp mode possible
Sources
References
sae:J2012