P2DC4
Starter/Generator Phase Y Current Sensor Circuit Range/Performance
P2DC4 says the phase Y current reading of the starter/generator is inside its electrical limits but fails a plausibility test. One way to test it is an energy balance: the power drawn or delivered on the phase side must match the current on the DC side. GM's eAssist machine compares the sum derived from its phase sensors with the DC-DC converter input and battery pack current; a gap above 40 A in 90 of 96 checks, run every 2.08 ms, sets a two-trip Type B code, and current control then continues without the sensors. GM measures U and W only, so this is an analogue, not P2DC4 itself, which no manufacturer documents publicly. A sensor with a gain error or a drifting zero is the usual suspect. Circuit: P2DC3; X and Z range: P2DC2, P2DC6.
Possible causes
- Phase Y current sensor reading consistently too high or too low high
- Zero offset of the phase Y sensor drifted medium
- Comparison value wrong because the DC-side current measurement is faulty low
Symptoms
- Warning lamp after two trips with the fault
- Noticeably weaker boost and smoother but slower restarts
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P2DC4
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.