P2DBB
Battery Charging System B High Voltage Interlock Circuit Intermittent/Erratic
P2DBB covers an interlock loop of charging system B that keeps dropping out and recovering, so its state flips between valid and invalid. The trigger is usually mechanical: a terminal with low contact pressure, a plug that is not fully latched, or a wire that only loses contact when the body flexes or the parts heat up. No manufacturer documents P2DBB publicly. A useful parallel is Mercedes bulletin LI54.10-P-067823 for the smart electric drive with the 22 kW charger option: loose low-voltage contacts at the charger produced sporadic interlock faults, filed there under the general codes P0A0A and P0A0E, and the car would not charge. CARB expects plug-in hybrids to catch faults that block charging. Steady faults are P2DB7 to P2DBA. Charging may stop for no visible reason.
Possible causes
- Loose or widened terminal in an interlock connector high
- Connector in the charging path not fully latched medium
- Chafed interlock wire that loses contact only with movement or heat medium
Symptoms
- Charging via path B stops without warning
- Fault comes and goes, often depending on temperature
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2DBB
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.