P2DB8
Battery Charging System B High Voltage Interlock Circuit Performance
P2DB8 means the interlock loop of charging system B carries a signal, but one that does not behave as the control unit expects. A common test switches the module's test source on and off and checks that the sensed level follows; a reading that stays put or hovers between the valid bands points to contact resistance, a half-seated plug or corrosion rather than a clean break. No manufacturer documents P2DB8 publicly. GM's Volt summary tables (2011, 2014) judge the A-side charging loop in exactly these two states, sourced and unsourced, against separate limits (P0D17, P0D18). The hard open is P2DB7, fixed low or high levels P2DB9 and P2DBA. While the fault is present, path B is normally not used for charging.
Possible causes
- Raised contact resistance in an interlock terminal high
- Plug in the charging path inserted only partway medium
- Corrosion or moisture in an interlock connector medium
- Test source or measuring stage of the module not working correctly low
Symptoms
- Charging via path B refused or interrupted
- Charging system warning message
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2DB8
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.