P2DB7
Battery Charging System B High Voltage Interlock Circuit/Open
P2DB7 reports that the high voltage interlock loop of charging system B is broken. Such a loop is a low-current wire run in series through the HV plugs and covers of a charging path; once it opens, the control unit treats the path as unsafe and keeps it switched off. B denotes a second charging path, for example a further on-board charger. No manufacturer documents P2DB7 publicly. The A-side code P0D15 shows a typical cause: on 2021–2023 XC40 Recharge cars Volvo found that the plant had not closed the latches on the AC high-voltage plug linking inlet and charger (TJ 36522, P0D1513), and AC charging was lost; seating and latching the plug fixed it. CARB wants plug-in hybrids to detect faults that disable charging. Signal-level faults of this loop are P2DB8 to P2DBB.
Possible causes
- HV connector in the charging path not fully seated or its catch not closed high
- Broken interlock wire or pushed-out terminal medium
- Service cover or HV cover of the charger not closed properly medium
- Fault in the interlock evaluation of the control module low
Symptoms
- No charging through charging path B
- Charging system warning in the instrument cluster
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2DB7
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.