P2DA5
Coolant Heater A Supply Voltage Circuit
P2DA5 concerns the feed that powers coolant heater A, the electric coolant heater with its own electronics found in hybrids and EVs. The heater's controller finds its supply input missing or outside the expected window and reports it as a circuit fault, unlike P2DA7, which rates the voltage level of the module. Which feed is meant is up to the maker. Texas Instruments shows that such heater modules run their logic from the 12 V rail and can watch that rail for leaving its operating range, while the heating elements draw from the HV battery. No manufacturer documents P2DA5 publicly. Typical findings are a blown fuse, a corroded pin in the low-voltage connector, a poor ground or an open HV fuse in the distribution box. The heater stays off until the feed is restored.
Possible causes
- 12 V or HV fuse for the heater open high
- Corroded or loose pin in the heater supply connector medium
- Poor ground connection of the heater electronics medium
- Supply input inside the heater electronics faulty low
Symptoms
- No heat from the electric coolant heater
- Cabin heat only when the engine of a hybrid runs
- Possibly lost communication with the heater stored at the same time
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2DA5
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.