P2DA1
Gear Shift Control Module B Supply Voltage Low
With shift-by-wire, the selector the driver touches is an electronic module; module B is a second one, such as a further selector station or a redundant unit. Allison's 6th-generation controls show such a pair: for module 2 they list performance, lost communication, incompatibility and invalid data (P085E, U0291, U0333, U0592), but no supply codes. P2DA1 means the 12 V feed of module B, as measured by the module or the transmission controller, is below its lower limit. No manufacturer documents P2DA1 publicly. Audi's selector lever J587 on 2019–21 A6/A7 shows how much depends on this voltage check: its evaluation logged faults and blocked range selection until new software was loaded. Battery, fuse, feed wire and ground come first.
Possible causes
- Weak 12 V battery or voltage dip during cranking high
- Corroded ground, loose connector or high-resistance feed to module B medium
- Fuse for module B blown or with poor contact medium
- Voltage evaluation in module software too strict low
Symptoms
- Shifter warning in the instrument cluster
- Range selection at the second selector ignored, vehicle stays in P
- Fault appears together with other low-voltage codes
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P2DA1
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.