P2D9B
Starter/Generator Phase U Current Circuit Intermittent/Erratic
P2D9B concerns phase U, the first phase of the starter/generator's main U-V-W group, when its current signal is unsteady rather than permanently out of range. GM's eAssist system, whose belt-driven machine appears in its tables as drive motor A, shows how a manufacturer separates hard limits from short events: the U sensor fails high or low beyond 440 A in either direction within 41.6 ms, while a fast, repeated overcurrent is handled by switching the inverter off for one 2.08 ms loop, counting the event and re-enabling, with the code following the third count. No manufacturer documents P2D9B itself publicly. Typical causes are a marginal plug contact, a damaged lead or a failing sensor. V and W intermittent: P2D9C, P2D9D; X to Z: P2D98 to P2D9A.
Possible causes
- Marginal contact in the phase U sensor connector high
- Phase U sensor lead with damaged insulation or a partly broken strand medium
- Phase U current sensor beginning to fail low
Symptoms
- Intermittent warning lamp, sometimes only after several trips
- Sudden loss of electric assist, returning after a restart
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P2D9B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.