P2D92
Starter/Generator Phase X Current Sensor Circuit High
P2D92 is set when the signal from the phase X current sensor of a belt or crankshaft starter/generator rises above the range the control electronics treat as valid. Such sensors, commonly Hall devices placed around the phase conductor, put out a voltage that tracks the current, so a value stuck near the top of the scale points to the circuit rather than to real current: a signal lead touching a supply voltage, a damaged connector or a sensor whose output has failed high. No manufacturer documents P2D92 publicly. The closest published logic is GM's eAssist belt machine, coded as drive motor A: a reading above 440 A within about 42 ms, Type B over two trips, after which current control carries on without the sensors. Low side: P2D95; Y and Z: P2D93, P2D94.
Possible causes
- Phase X sensor signal wire shorted to a supply or reference voltage high
- Current sensor output failed at the upper end of its range medium
- Damaged, corroded or water-contaminated connector at the starter/generator medium
- Fault in the evaluation circuit of the starter/generator control module low
Symptoms
- Warning lamp or MIL, often only after the fault has been seen on two trips
- Reduced electric assist and weaker restarts after automatic engine stop
- Automatic stop-start no longer active
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P2D92
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.