P2D7F
Charging Start Switch Circuit High
P2D7F reports a start switch line sitting above its allowed voltage, caused by an open wire or contact on a pulled-up input or by contact with a supply voltage. No manufacturer documents P2D7F publicly. With a start button the consequences run the other way than with the stop switch P2D7A. If the input idles high and the button grounds it, an open circuit hides every press, so a timer-delayed session cannot be brought forward. If the button drives the line high, the fault resembles a permanent start command, and a well-designed control unit will not act on a signal it has flagged as faulty, so charging may wait for the timer or the next plug-in. Honda's early charger shows why the input matters: there the start switch alone released charging. Low counterpart: P2D80.
Possible causes
- Open circuit in the start switch line or connector (pull-up design) high
- Start switch signal wire shorted to a supply voltage medium
- Start switch contact no longer closes medium
Symptoms
- Start button has no effect
- Charging begins only by timer or after re-plugging
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2D7F
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.