P2D7B
Charging Stop Switch Circuit Low
P2D7B is stored when the charging stop switch line is pulled below its permitted voltage, most often by a short to ground in the wiring, water in the switch or a contact that no longer opens on a switch that grounds the line when pressed. No manufacturer documents P2D7B publicly. Here the effect is mostly the reverse of P2D7A: on the common ground-switching layout a grounded line reads as a stop button held down. Toyota describes exactly this situation for its charging stop switch, where a permanent stop request blocks the start of charging, and adds a user procedure to override the stuck button. If instead low is the idle level, the stop request is lost. The high counterpart is P2D7A; the start switch has its own low code, P2D80.
Possible causes
- Stop switch signal wire shorted to body ground high
- Moisture or corrosion bridging the stop switch contacts medium
- Stop switch contact stuck closed (ground-switching design) medium
Symptoms
- Charging does not begin or ends immediately after plugging in
- Charging indicator shows no active session
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2D7B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
See repair cost, labour time and components?