Battery Charging System Negative Contactor D Control Circuit High
P2D76 means the control wire of minus contactor D shows more voltage than the module asked for. No manufacturer documents P2D76 publicly. GM's 2016 test for the minus charge contactor (P0D11) flags a power short when the idle output gets within 0.4 V of the supply. The effect hinges on which coil end is switched, which a GM patent leaves open: on a ground-side switched coil, a short to supply at the switched end means both coil ends sit at the same potential, so contactor D never pulls in and the driver may see overcurrent when it turns on; on a supply-side switched coil the contactor may close by itself. Either way charging via path D stops. P2D75 is the low case, P2D6F the plus side, P2D68 contactor C.
Possible causes
- Drive wire of contactor D touching a 12 V feed high
- Output stage that no longer switches off medium
- Crossed wires after work on the battery low
Symptoms
- Charging mode via contactor D blocked
- Fault appears as soon as ignition is on
- Charging or high-voltage warning
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2D76
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.