P2D75
Battery Charging System Negative Contactor D Control Circuit Low
P2D75 is stored when the drive line of negative charging contactor D reads low. No manufacturer documents P2D75 publicly. How serious this is depends on wiring: a GM patent shows the coil switch either on the supply side or on the ground side. If the module switches the ground side, a short to ground at that end bypasses the switch, so the coil can energise and minus contactor D can close although nothing was commanded; charging is then locked for safety. With supply-side switching the same short simply leaves the contactor open. CARB permits makers to combine open and short faults of an output under one code, so not every system sets a separate low code. Chafed wires and wet plugs are typical. P2D76 is the high case, P2D6E the plus side.
Possible causes
- Drive wire of contactor D shorted to ground high
- Moisture in the contactor D connector medium
- Output stage shorted inside the module low
Symptoms
- Charging locked
- Contactor may click without a command
- Fault worse in damp weather
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2D75
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.