P2D73
Battery Charging System Negative Contactor D Control Circuit/Open
P2D73 concerns the coil drive of negative charging contactor D: commanded and measured state of the line differ, pointing to an open wire, terminal or winding. No manufacturer documents P2D73 publicly. GM's test for the minus charge contactor (P0D11) is the direct analogue. In the 2016 tables it shares one entry with the plus contactor test and adds a current check: under 57 mA with the driver on means open, as does more than 4 V with it off. The 2011 Volt version only looked at the off state, with a 2 V limit. Both need 40 bad samples of 50 and cannot detect a ground short. The return pole of path D stays open. P2D74–P2D76 are the other drive faults, P2D6C the plus side, P2D65 contactor C.
Possible causes
- Open coil drive wire or loose terminal high
- Broken winding in minus contactor D medium
- Defective driver or current sensing in the module low
Symptoms
- Charging mode via contactor D not available
- Code present at every key-on
- Charging fault message
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2D73
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.