P2D71
Battery Charging System Negative Contactor D Stuck Closed
P2D71 indicates that negative charging contactor D has stayed closed after an open command, as happens when the contacts fuse. No manufacturer documents P2D71 publicly. A Toyota patent addresses a pitfall of this check: after DC charging the car asks the station to stop, but some stations keep feeding, and the leftover inlet voltage would wrongly suggest welded relays. Toyota therefore repeats a suspicious result after opening the main relays and draining the capacitor, then opens one charge relay at a time against a threshold of a few to a few tens of volts. A Ford patent adds the consequence: one weld locks charging, a weld on both poles also stops the car from driving. P2D72 is the opposite fault, P2D6A the plus side.
Possible causes
- Fused contacts in minus contactor D high
- Station kept supplying voltage during the check low
- Coil held on by a faulty output stage low
Symptoms
- Charging locked after a DC session
- Vehicle may refuse to become ready if the plus side is welded as well
- High-voltage warning at start-up
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended