P2D6F
Battery Charging System Positive Contactor D Control Circuit High
P2D6F says the supply wire to the coil of plus contactor D sits above its commanded level. No manufacturer documents P2D6F publicly. GM's 2016 drive test for plus contactor A (P0D0A) treats an idle output within 0.4 V of the supply voltage as shorted to power. Where the coil is switched on its supply side, one of the two layouts a GM patent describes, such a short energises the coil with no command, so plus contactor D may close and put the plus pole of its path, up to the inlet, on battery potential. Modules therefore lock charging when they see this code. Causes are a wire chafed against a 12 V line, swapped wires or a driver that stays on. P2D6E is the low case, P2D76 the minus side.
Possible causes
- Coil feed shorted to a 12 V supply high
- Output stage stuck switched on medium
- Wires swapped after a repair low
Symptoms
- Charging locked
- Contactor clicks unexpectedly with ignition on
- High-voltage warning possible
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2D6F
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.