P2D6B
Battery Charging System Positive Contactor D Stuck Open
P2D6B is logged when positive charging contactor D fails to close on command, leaving the plus pole of its charging path disconnected. No manufacturer documents P2D6B publicly. GM's Volt test for plus contactor A (P0D09) shows the usual principle: once charging and precharge are commanded on, the charger-side voltage has to climb, and the test fails when 8 of 9 samples, taken every 12.5 ms, stay below 10 V (Type A). The tricky part is attribution. CARB exempts failures that look identical whether the vehicle or the charging station is at fault, so the code is meant for faults that clearly lie inside the vehicle. Typical finds are pitted contacts, low coil voltage or a stuck armature. P2D6A is the welded case, P2D72 the minus side.
Possible causes
- Burnt contacts or jammed armature in plus contactor D high
- Insufficient coil supply voltage or poor ground medium
- Module software misjudging the voltage rise low
Symptoms
- Charging in the affected mode never starts
- Charging station reports an immediate abort
- Driving unaffected
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2D6B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.