Battery Charging System Negative Contactor C Control Circuit Low
P2D67 is stored when the drive line of minus charging contactor C sits lower than the module expects, typically because the wire touches ground or the connector has taken in water. No manufacturer documents P2D67 publicly. A separate low check is needed because the usual open-load test misses this fault: GM states in its 2011 Volt table for the minus charge contactor (P0D11) that the test cannot detect a short to ground. CARB, on the other hand, allows opens and shorts on outputs to share one code, so certain systems log this case under P2D65. The effect of the short depends on which coil end is switched: contactor C may remain open, or the output stage protects itself by cutting out. P2D68 is the high case, P2D60 the plus side.
Possible causes
- Drive wire chafed against the battery housing or body high
- Moisture or corrosion in the contactor connector medium
- Shorted turns in the coil of minus contactor C low
Symptoms
- Charging mode via contactor C refused
- Fault more frequent after rain or washing
- Charging warning in the cluster
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2D67
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.