P2D63
Battery Charging System Negative Contactor C Stuck Closed
P2D63 says negative charging contactor C has not opened on command; the return-side contacts are almost certainly fused. No manufacturer documents P2D63 publicly, and the Mercedes and Mazda bulletins that report a welded minus contactor B (P2BCC) do not mention C. Detection relies on isolating one pole at a time: Toyota opens the minus charge relay while the plus relay stays closed and treats it as stuck if the charging inlet voltage stays above a threshold; it repeats the test with the main relays open to exclude a charger that keeps supplying power. Hyundai uses the same pairing at the end of quick charging. With a welded minus pole the inlet is no longer isolated on that side, so the module blocks the path. P2D64 is the opposite fault, P2D5C the plus side.
Possible causes
- Fused main contacts of minus contactor C high
- Charger still supplying voltage during the check (false detection) low
- Coil output stage stuck on low
Symptoms
- Charging blocked after a session
- High-voltage warning at start-up
- Vehicle may not become ready if the plus side is welded too
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended