P2D5D
Battery Charging System Positive Contactor C Stuck Open
P2D5D means positive charging contactor C stays open although it was commanded closed, so the plus pole of that charging path never connects and the session fails right at the start. No manufacturer documents P2D5D publicly; Mazda, which lists the non-closing case for contactor B (P2BC6), says nothing about a C contactor. GM's comparable check for the Volt's plus contactor A (P0D09) illustrates detection: while the charger precharges, its terminal voltage ought to climb; if 8 of 9 readings, spaced 12.5 ms apart, remain under 10 V, the contactor counts as stuck open (Type A). CARB requires plug-in hybrids to detect charger faults that prevent charging. Suspects are burnt contacts, a weak coil feed and a jammed armature. Welding is P2D5C, the minus side P2D64.
Possible causes
- Contactor C does not pull in (burnt contacts, jammed armature) high
- Insufficient coil supply due to wiring or connector resistance medium
- Control software misjudges the precharge voltage low
Symptoms
- Charging in the affected mode does not start
- Charging station reports an aborted session
- Driving not affected
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2D5D
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.