P2D5B
Battery Charging System Positive Contactor C Circuit
P2D5B is the umbrella electrical fault for charging-system contactor C on the plus pole, a third plus-side switch next to contactors A (P0D07) and B (P2BC4). Which charging path C serves is left to each maker, and none states it in public: the bulletins that cite contactor B codes (Mercedes, Mazda, Audi) never mention a C contactor, nor do the published GM tables, and no document lists P2D5B itself. CARB obliges plug-in hybrids to catch charger faults that stop or curb charging. One GM patent assesses this kind of contactor from its coil current after a brief test pulse. Welding and failure to close have their own codes (P2D5C/P2D5D), coil-drive faults P2D5E–P2D61. Expect the charging mode behind C to be unavailable.
Possible causes
- Coil of contactor C open or shorted internally medium
- Damaged wiring or loose plug at the contactor or its module medium
- Output stage or software of the controlling module low
Symptoms
- One charging mode refused or aborted
- Charging or high-voltage warning in the cluster
- Driving otherwise normal
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2D5B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.