P2CC5
Generator Inverter Power Supply B Circuit/Open
P2CC5 concerns supply B inside the inverter that drives a hybrid's generator (motor-generator), typically a low-voltage rail feeding the gate drivers of the power transistors. Which supply gets the letter B is defined by the manufacturer; a second inverter channel or second generator would also fit. The code covers a missing supply or an interrupted feed. No manufacturer documents P2CC5 publicly. GM's 2019 hybrid tables show the principle with P0C0B for the drive motor A inverter: the IGBT module flags a bias fault when its supply dips below a threshold, and 0.168 s of failures within a 0.2 s window set a Type A code. CARB requires circuit monitoring of hybrid components. Without gate supply the generator cannot be switched at all. Supply A: P0E0F.
Possible causes
- Supply B for the gate drivers failed inside the inverter medium
- 12 V feed, fuse or connector of the inverter interrupted medium
- Poor ground connection of the inverter control electronics low
Symptoms
- Hybrid system warning light and MIL on
- Generator out of operation, vehicle may not become ready to drive
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2CC5
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.