P2CA7
DC/DC Converter Temperature Sensor E Circuit High
P2CA7 means the signal of DC/DC converter temperature sensor E is stuck above its upper limit. In a thermistor input fed through a pull-up resistor, an interrupted loop lets the voltage rise to the reference, so a pin pushed out of the connector, a broken conductor or a short to a supply line gives this result. The implied reading would be colder than any real surroundings. No manufacturer documents P2CA7 publicly; the converter sensors named in bulletins stop at letter D. CARB asks for range checks on such hybrid inputs. As a false cold value could hide real heat, the controller treats the temperature as unknown and limits the converter, leaving more of the 12 V load to the battery. P2CA6 is the low-side counterpart.
Possible causes
- Open circuit in the sensor E signal or return line, e.g. pushed-out pin high
- Signal line shorted to a supply voltage medium
- Thermistor of sensor E broken (open) medium
Symptoms
- MIL and hybrid or charging warning on
- Implausibly cold converter temperature in live data
- Reduced converter output, 12 V battery charge drops
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2CA7
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.