P2CA6
DC/DC Converter Temperature Sensor E Circuit Low
P2CA6 is logged when the voltage of DC/DC converter temperature sensor E sits below the lower edge of its window. Converter sensors are usually thermistors whose resistance falls as they warm, so a signal that collapses towards zero would mean a converter hotter than physically plausible. A chafed signal wire touching ground or an internally shorted thermistor is the normal explanation; genuine overheating would first produce smooth, believable readings. No manufacturer documents P2CA6 publicly, and published bulletins only go up to sensor D. CARB requires out-of-range detection on hybrid input components. Because the controller has to assume excess heat, it typically cuts converter power at once. The opposite signal fault is P2CA7.
Possible causes
- Signal wire of sensor E chafed through and shorted to ground high
- Thermistor of sensor E shorted internally medium
- Actual severe overheating of the converter, e.g. coolant loss low
Symptoms
- MIL and hybrid or charging warning on
- Converter switched off or strongly limited immediately after start
- Low 12 V voltage message on longer drives
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2CA6
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?