P2C98
Hybrid/EV Battery Disable Circuit High
P2C98 flags a battery disable line whose level is above the permitted range, usually through a short to 12 V or a sender that drives the line too high. Unlike the low case, the risk here can be hidden: if a high level means all clear, a stuck-high line would no longer pass on a real shutdown request. That is the point of such a wire in Volkswagen patent US9586481B2, which lets a crash signal open the contactor within 10–100 ms, and in Coda patent US20110304202A1, which disconnects the battery once airbag deployment is decided. The controller therefore flags the line even while driving seems normal; the CAN path normally remains as a backup. No manufacturer documents P2C98 publicly. CARB requires monitoring of hybrid components. Inspect the line for contact with feed wires.
Possible causes
- Disable line shorted to 12 V supply high
- Sending module driving the line above the valid level medium
- Input stage in the battery controller misreading the level low
Symptoms
- High-voltage system warning, often without noticeable driving fault
- Ready mode may be blocked after the next restart, depending on maker
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2C98
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.