P2C96
Hybrid/EV Battery Disable Circuit/Open
Besides commands over the vehicle network, many high-voltage batteries have a separate wired input through which another controller can force the contactors open. The best-known use is the crash signal: in Volkswagen patent US9586481B2 the battery opens its contactor 10–100 ms after a hard-wired crash signal, versus roughly 20–200 ms when the message arrives over CAN, and blocks reclosing until the stored fault has been erased. Coda patent US20110304202A1 also ties battery disconnection to the airbag deployment decision. What exactly feeds the disable line is up to the maker. P2C96 means this line is open. No manufacturer documents the code publicly. Many designs read a lost signal as a shutdown request, so the car may not become ready. CARB requires monitoring of hybrid components.
Possible causes
- Disable line or its connector at the battery pack interrupted high
- Sending controller (e.g. crash or airbag module) not driving the line medium
- Connector left unplugged after body or battery repair medium
- Input stage in the battery controller defective low
Symptoms
- Vehicle does not become ready to drive
- High-voltage system warning
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2C96
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.