P2C81
AIR System Pump Overtemperature Bank 1
P2C81 reports that the secondary air pump on bank 1 has become too hot. The pump is only meant to run for a short time after a cold start, until the catalyst lights off, as Hella describes; a pump with integrated electronics can sense its own temperature and protect its motor. No manufacturer documents P2C81 publicly, so thresholds are unknown; CARB requires monitoring of secondary air delivery. Overheating points to a pump that ran far longer than planned, for example after many short cold starts in a row or with a relay stuck on (P2444), to a blocked intake filter or outlet, to worn bearings that add friction or to water inside the pump. The pump may shut itself off, so no air reaches the exhaust during warm-up and cold-start emissions climb. P2C80 is the overspeed fault, P2C82 the supply fault.
Possible causes
- Pump running too long (many short cold starts, relay stuck on) medium
- Clogged intake filter or blocked outlet path medium
- Worn bearings or debris increasing friction medium
- Moisture or condensate inside the pump low
Symptoms
- Check engine light
- Pump stops early or does not run on the next cold start
- Hot smell or grinding noise from the pump
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P2C81
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.