P2C71
Drive Motor A Phase Z Current High
P2C71 reports overcurrent in phase Z of drive motor A, the last phase of the second winding set. No manufacturer documents P2C71 publicly. Once overcurrent is detected the inverter has to bring the machine into a safe state, and the Mitsubishi Electric patent on dual-winding drives deals with exactly that: when the battery link opens, each winding set is moved in steps from a phase short circuit to all switches off, at different times, so that the voltage induced by the spinning rotor cannot damage the inverter. For the driver this means a sudden loss of drive power and a warning. Ford's limits for the U/V/W case, 600 A for 400 microseconds, show how fast such checks are. Suspect a shorted switch, a winding or lead short, or a sensor error. P2C70 is the low side, P2C6B and P2C6E are X and Y.
Possible causes
- Shorted power semiconductor in the Z leg medium
- Short in the phase Z winding or lead, to another phase or ground medium
- Phase Z current sensor reading too high or noisy medium
- Inverter control software reacting wrongly to transients low
Symptoms
- Sudden loss of drive power with hybrid or drive warning
- MIL on, vehicle may not restart into ready mode
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2C71
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.