P2C70
Drive Motor A Phase Z Current Low
P2C70 means phase Z of drive motor A delivers too little current although the inverter is commanding it. No manufacturer documents P2C70 publicly. GM's missing-phase check for the U/V/W set shows the principle: the 2016 Volt only judges a phase while the rotor angle sits near that phase axis and enough current is requested, and fails it when the peak stays under 9 A, Type A with MIL after one trip. The window matters, because a phase near its zero crossing carries little current even when healthy. For the Z phase of the second set the most likely finds are an open lead or terminal, a burnt connection at the inverter or a sensor stuck at zero. Torque drops and the motor may vibrate. P2C6F is the general Z code, P2C71 the high side, P2C6A and P2C6D the low cases of X and Y.
Possible causes
- Phase Z lead or terminal open or burnt high
- Phase Z current sensor stuck near zero medium
- Z leg of the inverter not switching medium
- Open phase Z winding in the motor low
Symptoms
- MIL and hybrid or drive warning
- Loss of torque and vibration from the motor under load
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2C70
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.