P2C47
Battery Isolation/Voltage Stabilization Control Circuit Intermittent
With P2C47 the module saw the command line of the isolation or stabilization stage drop out and come back, rather than stay permanently open or shorted. Loose terminals, a cracked solder joint in the isolator or a ground strap that only loses contact when the engine rocks on a restart are typical, and the fault often sets only while driving or on bumpy roads. The battery area is a harsh place for connectors: heat, vibration and acid vapour. No manufacturer documents P2C47 itself; Ford's PowerBoost F-150 bulletins under P2C44 show how much a single ground path (GD132) matters in this circuit. CARB lets makers suspend other monitors at low system voltage, so a flickering supply can also leave readiness monitors incomplete. Wiggle tests with live data help to find the spot.
Possible causes
- Loose or spread terminal in the isolator connector high
- Ground strap or ground point with intermittent contact medium
- Cracked solder joint inside the isolator low
Symptoms
- Fault indicator comes and goes
- Stop-start works only sometimes
- Readiness monitors may stay incomplete
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2C47
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?