P2C41
Fan 3 Performance/Stuck Off
P2C41 judges the outcome rather than the wiring: fan 3 is commanded on and its circuit checks out (otherwise P0482, P0695 or P0696 would appear), yet the controller sees little or no response, usually through speed feedback from a fan module or a missing current draw. No manufacturer publicly documents this code. Audi's 2022–2023 e-tron GT shows what tends to be behind such faults: road debris entering through the wheel housing liner jammed the radiator fans, logged there under P2B30/P2B32. Porsche renewed corroded engine-compartment blowers in pairs on the 2017 911 after a fan failure warning. CARB asks for outputs to be checked for functional response where feasible. Rising temperatures under load follow. Speed deviations are P2CBB/P2CBC.
Possible causes
- Fan blades blocked by dirt, stones or leaves high
- Worn or seized fan motor, corrosion from moisture medium
- Fan control module does not drive the motor medium
- Weak power or ground supply to the fan low
Symptoms
- Engine temperature climbs in traffic or under heavy load
- Weak air conditioning at standstill
- Warning lamp or fan failure message
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2C41
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.