Powertrain
generic / SAE
P2C36
Crankcase Pressure Sensor B Circuit Intermittent/Erratic
The ECM detects a circuit intermittent/erratic fault on the crankcase pressure sensor b circuit. Reading cannot be used reliably for control.
SystemPowertrain
Typegeneric / SAE
GroupP2
Range / numberC / 36
Possible causes
- Sensor connector not seated high
- Noisy ground reference medium
- Connector with intermittent contact under vibration low
Inspection / repair
- Difficulty: easy
- DIY: possible
- Estimated cost: 60–300 €
- Estimated time: 0.3–1.5 h
- Component: crankcase pressure sensor b
- Component: wiring harness
- Component: ecm
- MIL / check engine light
- emissions-relevant
- drive cycle required
Sources
References
sae:J2012