P2BCF
Battery Charging System Negative Contactor B Control Circuit Range/Performance
P2BCF points to a control circuit on negative charging contactor B that is neither open nor shorted yet still implausible: coil current, line voltage or switching time fall outside the window that belongs to the commanded state. No manufacturer documents P2BCF publicly, and no published GM table has such a check for a charging contactor coil. CARB asks for rationality checks in addition to circuit checks on plug-in charging components. GM's patent on diagnosing the battery disconnect unit shows the kind of evidence available: how the coil current rises after a brief pulse, held against a stored profile, separates a healthy contactor from a sluggish one. A shifted coil resistance, corrosion in the connector and a poor module ground are typical. Opens are P2BCE, low and high P2BD0/P2BD1, the plus side P2BC8.
Possible causes
- Coil resistance of negative contactor B shifted medium
- Corrosion or contact resistance in the control connector high
- Poor ground of the controlling module low
Symptoms
- Charging drops out or will not begin
- Charging fault message from time to time
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2BCF
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.