P2BCC
Battery Charging System Negative Contactor B Stuck Closed
P2BCC says negative charging contactor B is still closed although the module ordered it open – in practice fused contacts on the return side. Mercedes-Benz lists it in the DC charge connection unit next to P2BC5 and P0E8929 (DC input current too high); the plug-in hybrid, EQB or eSprinter then cannot be started after DC charging. The bulletins name ripple and overvoltage from the station and contacts that open too late, and call for a software update and a contactor-fault reset instead of a new unit. Mazda names it OBC contactor (−) stuck on in the same bulletin and also prescribes a new Junction Box No. 2. Hyundai and Toyota patents find such welding by opening one pole while the other stays closed and checking the voltage behind it. P2BC5 is the plus side, P2BCD the reverse fault.
Possible causes
- Contacts of negative contactor B welded at the end of charging high
- Charging module software (Mercedes update) medium
- Current ripple or overvoltage from the DC station medium
Symptoms
- Vehicle will not start after DC charging (Mercedes)
- High-voltage system warning
- Charging blocked
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2BCC
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.