P2BB1
Alternative Fuel Consumption Too High
P2BB1 is set when the alternative fuel store, typically a CNG cylinder, loses more gas than the injected quantity can account for. The main suspicion is a leak between tank and injectors, which is why this check doubles as a safety monitor. FCA's patent US9284895 describes it for natural gas vehicles: tank pressure is sampled at two moments, the gas mass delivered per cylinder charge is integrated over the same period, and a leak is flagged when actual use exceeds the expected figure by more than a tolerance, about 3 % or 2 mg per second and cycle in its example. No carmaker publishes P2BB1 itself. A sensor that exaggerates the pressure drop or an injector stuck open can produce the same result. Smell gas: park outdoors and have it checked. Too little use is P2BB0.
Possible causes
- Gas leak at fittings, lines, regulator or tank valve high
- Gas injector leaking or sticking open medium
- Tank pressure or temperature sensor exaggerating the pressure drop medium
Symptoms
- Gas range much shorter than usual
- Gas smell around the vehicle
- MIL on, gas mode may be locked out
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2BB1
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.