P2B5A
Engine Coolant Flow Control Valve Control Circuit Low
P2B5A stands for a short to ground in the control wiring of the coolant flow control valve motor. GM's 2025 table for the 3.0-litre Duramax describes the detection: the driver sees more than 9 A flowing, which it interprets as one motor wire touching ground, and 80 out of 100 samples at 12.5 ms set a two-trip Type B fault once relay voltage exceeds 11 V. Unlike P2B58, where the motor itself draws too much current, the cause here is normally insulation damage in the harness, a pinched wire near the valve or water in the connector. The valve stays in its last or default position, so coolant distribution becomes fixed. Short to power is P2B5B, open circuit P2B59.
Possible causes
- Motor wire chafed or pinched against ground high
- Coolant or water in the valve connector medium
- Internal short to housing in the valve motor low
Symptoms
- MIL on after two drives
- Engine temperature control fixed, slower warm-up or higher running temperature
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2B5A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?