P2B35
A Camshaft Profile Actuator B Control Circuit High Bank 1
P2B35 is the short-to-voltage counterpart for intake-side actuator B on bank 1, the second of the sleeve-shifting solenoids on camshaft A. In GM's L3B tables (2019 and again 2025) this test runs while the output is off: if the control line shows 0.5 Ω or less towards the controller supply, a short to power is assumed, and 4 hits in 5 samples set a Type A code with the warning lamp on in the same drive. A wire rubbing against a powered circuit in the harness or an internal short in the solenoid are typical reasons. Because the control line no longer behaves as commanded, the cam sleeve cannot be moved reliably and this actuator drops out of lift switching. Open and ground faults are covered by P2B33 and P2B34.
Possible causes
- Control wire chafed against a powered circuit in the engine harness high
- Internal short in actuator B medium
- Output stage in the engine control module faulty low
Symptoms
- MIL on during the drive in which the fault appears
- Intake lift profile no longer changes as commanded
- Higher fuel use because cylinder deactivation is blocked
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2B35
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.