P2B30
Fan 1 Stuck On
P2B30 states that radiator fan 1 does not follow the command to stop or to change speed, as judged from its speed feedback or module diagnosis. The classic electrical background is a welded relay contact or a fan module that keeps driving the motor. Audi uses the code on the 2022–2024 e-tron GT and RS e-tron GT, stored in thermal management J1024 (address 00C5) as symptom 59328: road dirt and stones entering through the wheel housing liner grille block the fan mechanically, so commanded and reported operation no longer match. Owners notice weak cabin heating or cooling, less drive power or a battery that will not charge fully. Audi fits revised fans, shrouds, liners and protective caps. CARB requires fan outputs to respond correctly to commands. Fan 2 has P2B32, the stuck-off case of fan 1 is P2B2F.
Possible causes
- Road debris jamming the fan (Audi e-tron GT) high
- Fan relay contacts welded closed medium
- Fan control module ignoring the off command medium
Symptoms
- Fan keeps running after switch-off, draining the 12 V battery
- Weak cabin heating or cooling on electric vehicles
- Grinding noise from the front wheel area
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2B30
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.