P2B2F
Fan 1 Performance/Stuck Off
Unlike the circuit codes P0480, P0691 and P0692, P2B2F judges the result: radiator fan 1 is commanded on but does not deliver, up to not turning at all. Detection uses fan speed feedback from a PWM or LIN fan module, or the missing temperature drop when the fan should be cooling. FCA lists P2B2F-00 with the MIL for the 2017–2018 Alfa Romeo Giulia and 2018 Stelvio with the 2.0 L turbo four (EC2) in bulletins 18-097-19 and 18-026-20, among other codes fixed by a PCM software update; no thresholds are published. CARB requires output components such as fans to be checked for proper functional response. Beyond software, a seized motor, debris in the blades or a failed fan module are the usual finds. Overheating in traffic and weak A/C at idle follow. The stuck-on case is P2B30.
Possible causes
- Fan 1 motor worn or seized, or blades blocked by debris high
- Fan control module or relay not switching the motor medium
- Engine software judging the fan wrongly (FCA 2.0 L) medium
- Poor power feed or ground at the fan low
Symptoms
- MIL
- Rising coolant temperature in slow traffic
- Weak air conditioning at standstill
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P2B2F
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.