P2AF9
Starter Relay D Control Circuit High
P2AF9 indicates that the control line of starter relay D sits at supply voltage although the driver is switched off, mostly a short to a 12 V circuit or a leaking driver stage. With ground-side switching the module can then no longer energise the coil, because both coil ends see battery voltage; with supply-side switching the coil may stay energised and keep a cranking path live, which is the more critical case for starter and ring gear. No manufacturer documents P2AF9 publicly. CARB asks for output components to be tested for shorts as well as opens, and GM, as an analogue, treats a path of at most 0.5 Ω toward supply on its starter relay outputs as a short when the driver is off (Type B, 40 of 50). Check the wire for chafing against live circuits, then relay and module output.
Possible causes
- Control wire chafed against a live circuit high
- Leaking output driver in the control module medium
- Internal fault in relay D low
Symptoms
- Stop-start disabled
- Starter may not engage, or in rare cases keep running
- Stored code, lamp depending on manufacturer
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P2AF9
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.